Background Bacteria and bacterial components have been associated with the activation of coagulation factors and initiating the blood clot formation. The aim of this study was to investigate whether bacterial populations are present in clots retrieved from patients that have suffered a large vessel occlusion acute ischemic stroke (AIS). Materials and methods Clot samples were collected from 20 AIS patients who underwent clot retrieval with mechanical thrombectomy. Patient clinical demographic details were noted. Expression of bacterial 16S rDNA was analyzed by standard and real-time polymerase chain reaction (PCR). Gram staining was performed to identify Gram-positive and Gram-negative bacteria. Results Both the real-time and standard PCR demonstrated no expression of 16S rDNA in any of the 20 clots samples from AIS patients. Gram staining results showed no expression of Gram-positive or Gram-negative bacteria present in the clot samples. Conclusion Our current study found no bacteria populations in the clots of AIS patients.